Warmly welcome to use the latest version of the Vent-Axia specification range catalog. As part of Europe’s continued promotion of energy efficiency, ventilation equipment exceeding 30 watts falls within the scope of the energy-related product directive that came into effect on January 1, 2016. This legislation sets a series of minimum performance standards for fans and ventilation equipment according to two sets of legislation; “residential” ventilation and “non-residential” ventilation. As a result of the legislation, we have reviewed our products and updated them as needed to ensure they meet the requirements. Based on Vent-Axia’s motivation to provide our customers with the best solutions, we took this opportunity to update and improve some products while making them comply with ErP regulations. We have also improved the way we provide some of these products-giving you more choices and flexibility in how to store and sell products. This edition of the specification range catalog shows our continued investment in products and services to improve and increase our already comprehensive range. In this catalog, we have concentrated our low-carbon residential and non-residential products in one place, providing what we believe is the best solution for today’s various specifications. We have introduced many new models that extend our well-proven traditional products and further expand our capabilities through numerous innovations in Vent-Axia Lo-Carbon and energy-efficient ventilation solutions. For example, EKF kitchen fan has built-in EC motor speed regulation, the highest rated high temperature is 120 degrees, the motor is out of air flow, and the specific fan power is less than 1 W/l/s; we believe that there is no better solution. We thank you for your habit and feedback all the time, and we are ready to answer any questions you have at any time. If you need to contact us, please send an email to sales@vent-axia.com, or contact your local representative, they will be happy to help you. Kind regards, Mark Hoskins Managing Director Why choose Vent-Axia Vent-Axia to provide heat recovery solutions to countries around the world, and the building regulations of these countries have required the most effective, sustainable and energy-saving ventilation solutions. We are always with you • Unparalleled customer service • Industry-leading design support • Provide on-site support and solution availability • With the most extensive distribution network of all manufacturers in the UK, we feel that we can provide the products you need anytime, anywhere Proud of product solutions • Regardless of the product category, we have the most energy-efficient solutions • Unique solutions for all your buildings • We are absolutely focused on the end user, we strive to produce the quietest and most comfortable products for living Incomparable customer service, on-site support, industry-leading design, and the widest range of ventilation solutions for the UK power distribution network
Legislative Approval Document F 2010-Ventilation Method The purpose of this regulation is to ensure that adequate ventilation methods are provided for people in the building. According to the document, ventilation is “removal of stale air in a building and replacing it with fresh outdoor air”. By providing fresh outdoor air to breathe, ventilation helps to dilute and remove pollutants and reduce humidity/condensation, which creates a more pleasant environment and relief for asthma and allergy sufferers. Part F is a performance-based overall architectural solution that not only explains what should be achieved, but also how to achieve this goal. The pollutants in today’s modern houses have caused these changes, and the types and acceptable levels of pollutants are now detailed in Part F 2010 of the approval document. Nitrogen Dioxide (NO 2) Carbon Monoxide (CO 2) Total Volatile Compounds (TVOC) Biological-Sewage (Body Odor) In ADF 2010, the ventilation requirements for newly built properties are based on the analysis of building area, number of bedrooms and occupants, refer to The entire residence. ADF 2010 covers four systems, including intermittent exhaust fans, passive chimneys, continuous mechanical exhaust ventilation (MEV) and mechanical ventilation with heat recovery (MVHR). A guide called “Household Ventilation Compliance Guide” can be used. This includes installation practices as well as signing and commissioning. Efficiency regulations require buildings to be better sealed and airtight. In ADF 2010, there are two ventilation rates according to the design permeability of the building. Properties with a permeability exceeding 5m 3 h/m 2 (more leaky properties) have a ratio, while properties with a permeability lower than 5m 3 h/m 2 (closer properties) have a higher ventilation rate. The practical result of this means that in confined properties, the following applies: • The trickle vents of intermittent fans can be increased by up to 50% • MVHR rate increases. MEV in properties of 5m 3 h/m 2 or more does not apply. A trickle vent is required. The guide can be used for the ventilation of the basement of the house and the trickle ventilation of the replacement window. Meet the requirements of Part F. The installation performance meets the ventilation rate quoted in the document. This means that the ventilation must be commissioned and signed by qualified personnel. With the improvement of air tightness, the acoustic characteristics are also improved, thereby reducing the external noise entering our house. However, this will make any noise generated inside the property more noticeable, so in Part F, the maximum noise level of the trickle velocity of the continuous ventilation system is set to 35dB(A). Document L-Fuel and Electricity Protection approved in 2013. These documents set the minimum performance level for ventilation efficiency and reduction of system consumption. These regulations have brought some major changes to the ventilation industry to improve air quality and energy efficiency. Part L-Overview • Target emission rates and textile energy efficiency standards aim to reduce carbon emissions by 6% • Non-residential building service compliance guidelines show specific fan power requirements. The minimum heat recovery efficiency of the EN308 test standard • The specific fan power (SFP) target of the new or replaced commercial kitchen extraction system is 1 W/l/s • The minimum energy efficiency level of all ventilation systems. The SFP of intermittent fans for new and refurbished applications must be less than 0.5 W/l/s.
4 As part of Europe’s continued promotion of energy efficiency, as of January 2016, ventilation equipment exceeding 30 watts has now been included in the scope of the energy-related product directive. The legislation stipulates a series of minimum performance standards for fans and ventilation equipment based on two sets of legislation; “residential” ventilation and “non-residential” ventilation. As a result of the legislation, we have reviewed our products and updated them as needed to ensure they meet the requirements. The major changes mean that many products have designated replacement motors or have been updated to achieve speed control. However, we have ensured that the installation method is not affected. Through the review, we also took this opportunity to rationalize our scope when needed. All related products in this document have been updated in accordance with the requirements of ErP regulations. Please note that due to changes in products caused by ErP, we will have a transition period. We will go from the old model to the new model. Any inventory you currently hold will not be affected by this regulation and can be sold normally. Residential products Residential products have a secondary directive that requires certain products to carry an energy label, as described below: Residential Scope-Small Fans Most small residential fans are not affected by the legislation, because any equipment below 30 watts is currently not available Within range. However, information about them has been recorded and can be found at www.vent-axia.com/erp. Duet and Gemini fans have been delisted, but can still be used as spare parts, so please contact sales@vent-axia for more information. MVHR and MEV products are indeed within the scope of legislation and will carry energy labels. There are some minimum energy efficiency requirements and summer bypass requirements for heat recovery models. A few of our products have been updated to ensure that they meet these requirements. The following products have been discontinued: • Kinetic E energy efficiency grade products within the ErP range now require a rating that shows their energy efficiency grade. This information is called the “SEC rating” and is provided on all product literature and energy labels. The SEC category of a product is affected by the way the product is controlled. This is called Local Demand Control (LDC) and indicates how many “sensors” the fan should have. Regulations require that single room fans, such as bathroom fans, should be equipped with at least one sensor. Pipeline devices, such as MEV devices, require multiple sensors. For example, pull cord/light switch or humidistat. In our literature, if additional LDC is added to the product, we will display the rating where appropriate. In these cases, you will see a table similar to the one below with a heading (including LDC). So you can choose the most effective option according to your needs. Example of SEC rating Model SEC rating SEC rating (including LDC) HR200 CB 1 1 Manufacturer name 1 2 Model name 1 3 Energy efficiency class 1 4 Maximum flow rate 1 5 Sound level 2016 1254/2014 dB ENERGIA · ЕНЕГИЯ · NERGIA · РГИЯ ENERGY · ENERGIE m 3 /h C Vent-Axia 443028L 66 252 1 3 1 1 1 4 1 5 1 2 Energy Related Products Directive (ErP)
5 Non-residential non-residential products have established minimum performance and efficiency levels, but there is no requirement to introduce energy labels. Some products have been updated with new motors and enabled speed control. The non-residential area is divided into many different categories according to its application and function. These can be described as follows: 1. Fan 2. One-way ventilation device 3. Two-way ventilation device 1. Fan These products have a simple housing that can guide air in and out of the impeller. Examples include axial fans and chassis fans. These examples are beyond the scope of legislation. Changing the way we sell products ErP regulations give us the opportunity to review our product range and in some cases enable us to improve our inventory and sales methods. Examples of this include T series and standard range fans. You can now buy them as whole products or in modular form. The entire product can be purchased using the existing part number that you have been using. Alternatively, you can purchase only the motor core or only the installation kit according to your needs. If you are not sure about the new part number, don’t worry, because we will tell you what the new part number is. But in some cases, you may receive more than one box.
6 2. Unidirectional ventilation device This includes products with only one direction, and there is an auxiliary housing around the fan. This is the product category that requires the most changes. The impact of efficiency legislation means that it is almost impossible to comply with the use of forward-bending AC centrifugal fans. Therefore, we have switched to back-bending centrifugal fans in all AC box fan series. This means changes in box size and performance adjustments across the entire range. Therefore, the product series has been updated: ACQ/ATQ QP/QPTW We have many product series that are close to the end of their life cycle. We take this opportunity to rationalize them and provide suitable alternative series when possible. The following product series are no longer available: VMD RMV GRB GDB GRD Other product series have been rationalized to provide a solution, including: ARH-rationalized to MFQ RBH-rationalized to RMH 3. Two-way ventilation device supply and extraction of these product series, such as Heat recovery. A minimum energy requirement is now set for heat recovery efficiency. Any product with an efficiency of 67% or lower does not meet the requirements. The Totus 2 and ERV-HIBOX series are not affected by these changes, but the low-efficiency heat recovery ERV-BOX products have been discontinued. Minimum heat recovery efficiency 67% 67% Energy Related Products Directive (ErP)
7 Since the first introduction of building codes for ventilation in 1992, the situation has changed a bit. The following is an overview of the changes since 2006. 2006-Part F includes continuous ventilation for the first time. The ventilation system was installed by technicians, but performance data has never been tested. The change in part L means that SAP Q products can be used as part of residential SAP calculations. 2010-Design, install and ensure its correct use. With increasing energy efficiency and decreasing air permeability of residential designs, ventilation systems now require specific flow rates, and there is an increasing demand for efficient heat recovery to help reduce DER. It is now necessary to install ventilation properly and record and measure the installation situation, in addition to providing guidance to residents on how to operate it. 2013-New Part L requirements mean reducing air leakage and improving air tightness. These trends continue to drive higher-efficiency adoption, and as the beneficial air from leaks is further reduced, the importance of installation increases. 2016—According to the commitments made at the recent COP21 meeting and the Paris climate agreement, the focus on decarbonization and energy efficiency will continue. Building energy performance directives and energy-related product directives have an impact on the performance and efficiency standards of ventilation. These driving factors will continue to develop and are expected to be transformed into standards in the future, which means more attention to energy efficiency. The commitment to zero-carbon construction in 2019 will mean that the F and L parts of the building code may be revised. When we concentrate on reducing the energy used in buildings, the risk of airtight, well-insulated buildings becoming a potential cause of respiratory problems increases. Therefore, the importance of a well-designed and well-installed system that operates as designed has increased. This will lead to more emphasis on ability when installing ventilation equipment, and may promote the improvement of the training methods of installers. Things to remember • Airflow performance • Minimum energy efficiency limit • Good installation • Future directions for tenant use
8 LO-CARBON residential fans 12-35 Lo-Carbon Svara- up to 30l/s Lo-Carbon iQ- up to 37l/s continuous operation Lo-CarbonVA100 ® /SELV-up to 21l/s Lo-CarbonSilhouette ® 100/SELV-up to 30l/s Lo-Carbon Centra ® /SELV-up to 15l/s continuous operation NEW Lo-Carbon Revive/SELV-up to 60l/s Lo-Carbon Solo ® Plus/SELV- up to 21l/s continuous operation No. 14-15 Page 16-17 Page 18-19 Page 20-21 Page 22-23 Page 24-25 Page 26-27 Lo-Carbon Minivent- up to 31l/s Lo-Carbon LEDVent-A-light- up to 31l/s Lo-Carbon Quadra ® /SELV-up to 63l/s continuous operation Lo-Carbon Silhouette 125- up to 44l/s Lo-Carbon VA150- up to 64l/s Lo-Carbon Silhouette ® 150-up to 65l/s page 28 Page 29 Page 30-31 Page 32 Page 33 Page 34-35 dMEV, MEV and PIV systems 36-55 Lo-Carbon Centra ® /SELV-up to 15l/s (54m 3 /h) continuous operation low Carbon response-up to 13l/s (47m 3 /h) continuous operation Lo-Carbon Multivent- up to 120l/s (432m 3 /h) Multivent- up to 123l/s (443m 3 /h) Lo-Carbon Sentinel ® Mult ivent/ Plus-up to 165l/s (595m 3 /h) Lo-Carbon Multivent MVDC-MS/MSH- up to 121l/s (436m 3 /h) page 38-39 page 40-41 page 42-43 page 44 -45 pages 46-49 pages 50-51 pages Lo-Carbon PoziDry- up to 50l/s (180m 3 /h) Lo-Carbon PoziDry Compact- up to 34l/s (122m 3 /h) pages 52-53 pages 54-55 Single room dMVHR 56-63 Lo-CarbonTempra/SELV- up to 15l/s (54m 3 /h) continuous operation HR200WK- up to 61l/s (220m 3 /h) HR300- up to 83l/s (299m 3 / h) page 58-59 page 60- Table of contents on pages 62-63 on pages 61
9 MVHR devices for residential and commercial applications 64-115 Lo-Carbon Sentinel Kinetic ® Advance- up to 115l/s (414m 3 /h) pages 66-67 Lo-Carbon Sentinel Kinetic ®-up to 76l/s (274m3) h) Pages 72-75 Lo-Carbon Sentinel Kinetic ® FH-up to 93l/s (335m 3 /h) Pages 76-79 Lo-Carbon Sentinel Kinetic ® Plus-up to 136l/s (490m 3 /h) Page 80 Page-83 Lo-Carbon Sentinel Kinetic ® High Flow Rate-Up to 195l/s (702m 3 /h) Page 84-85 Lo-Carbon Sentinel Kinetic ® Range Hood-Up to 76l/s (274m 3 /h) Page 86- Page 89 Lo-Carbon Sentinel Kinetic ® level-up to 98l/s (353m 3 /h) Page 90-95 Lo-CarbonKinetic ® Plus E-up to 141l/s (508m 3 /h) Page 96-99 Integra ®- Up to 48l/s (173m 3 /h) page 100-101 NEW Integra ® Plus EC-up to 130l/s (54m 3 /h) page 102-103 HR100R/RS- up to 18l/s (65m 3 /h) page 104 -105 HR200V- up to 103l/s (371m 3 /h) page 106-107 HR500- up to 250l/s (900m 3 /h) page 108-109 HR500D- up to 174l/s (626m 3) page 110-111 HR500EP /IP- Up to 244l/s (878m 3 /h) Page 112-113 HR500DP- Up to 333l/s (1,199m 3 /h) Page 114-115 Pipes and fittings 116-141 Heating range 142-161 Bluethermal ® Floor heating-up to 3,300W page 144-149 heated towel rail-page 15 radiant heater-up to 6,000W page 152-153 Opal ® aluminum radiator-up to 1,500W page 154 Optimax ® Pl us Panel heater-up to 2,000W Page 155 Optimax ® Plus combined storage heater-up to 3,400W Optimax Page 156 Storage heater-up to 3,400W Page 157 Base heater-up to 2,000W Page 158 Warm curtain- Up to 6,000W Page 159 Convection heater-Up to 2,000W Page 160 Portable fan heater-Up to 2,000W Page 161
10 Catalog COMMERCIAL RANGE 162-205 ACM ® 100-200-up to 240l/s (864m 3 /h) Page 164-165 ACM ® 250-315-up to 653l/s (2,351m 3 /h) Page Powerflow- up to 340l/ s (1,220m 3 /h) Pages 168-169 Lo-Carbon T Series® Window Type-Up to 430l/s (1,550m 3 /h) Pages 172-173 Lo-Carbon T Series® Wall Model-Up to 460l /s (1,650m 3 /h) Page 174-175 Lo-Carbon T-series® roof model-up to 330l/s (1,194m 3 /h) Page 176-177 Lo-Carbon T-series® panel model-up to 490l/ s (1,761m 3 /h) Pages 178-179 Traditional T Series® Window Type-Up to 449l/s (1,615m 3 /h) Pages 182-183 Traditional T Series® Wall Model-Up to 485l/s (1,745 m 3 /h) Page 184-185 Traditional T Series® Roof Model-Up to 412l/s (1,485m 3 /h) Page 186-187 Traditional T Series® Panel Model-Up to 524l/s (1,885m 3 /h) Page 188-189 Traditional T-Series ® Darkroom Model-Up to 314l/s (1,130m 3 /h) Page 190-191 Traditional T-Series ® Inline Model-Up to 620l/s (2,230m 3 /h) Page 192-193 Page Super T series-up to 1372l/s (4,940m 3 /h) Page 194-195 Traditional standard window model-up to 433l/s (1,560m 3 /h) Page 198-199 Traditional standard roof model-up to 314l/s ( 1,130m 3 /h) Page 200-201 Traditional standard wall model-up to 491l/s (1,767m 3 /h) Page 202-203 Traditional standard panel model-up to 531l/s (1,910m 3 /h) Page 204-205 Accessories and Controllers-Residential and Residential COMMERCIAL SYSTEMS 206-225 Panel and Chassis Fan Series 226-301 Sabre Panel Mount Sickle Fan (VSP)-Up to 5.71m 3 /s (20,556m 3 /hr) No. 228- Page 233 Sabre Sickle Short Shell Fan (VSC)-up to 5.81m 3 /s (20,916m 3 /hr) Page 234-241 Long Shell Axial Fan (LCA)-up to 36.01m 3 /s (129,600m 3 /hr) hr) Pages 242-271 Kitchen Axial Fan (KAF)-Maximum 5.93m 3 /s (21,348m 3 /hr) Pages 272-275 Bifurcated Axial Fan (BIFA)-Maximum 19.10m 3 /s ( 68,760m 3 /hr) pages 276-301
11 In-line fan series 302-341 Low-carbon kitchen box fan (EKF)-up to 3.69m 3 /s (13,284m 3 /hr) Page 304-311 New Acoustic In-line Fan (ACQ)-up to 1.5 m 3 /s (5,400m 3 /hr) Page 312-317 Eco Mix Flow Fans (eMF)-up to 5.63m 3 /s (20,268m 3 /hr) Page 318-323 Powerflow Duct Fan (ACP)-up to 0.34m 3 /s ( 1,220m 3 /hr) Page 324-327 EuroSeries ® (SDX) in-line centrifugal fan-up to 0.35m 3 /s (1260m 3 /hr) Page 328-331 Slimpak® In-in-line centrifugal fan (SLP)-up to 0.38m 3 /s (1,368m 3 /hr) Page 332-335 Mixed flow fan (MFQ)-up to 3.67m 3 /s (13,212m 3 /hr) Page 336 341 Dual fan series 342-355 SENTINEL D-BOX 356- 383 New Acoustic Direct Drive Double Fan (ATQ)-up to 1.35m 3 /s (4,860m 3 /hr) Page 344-349 Power Double Fan (TDF)-up to 3.52m 3 /s (12,672m 3 /hr) Pages 350-353 Trakmaster Dual Fan Controller Pages 354-355 Sentinel D-Box Single Fan-Up to 1.49m 3 /s (5,364m 3 /hr) Pages 362-371 Sentinel D-Box Dual Fan-Up to 1.20m 3 /s (4,320m 3 /hr) Page 372-381 Sentinel D-Bo x Sensor and Control Page 382-383 SENTINEL TOTUS 2 D-ERV 384-401 Roof Fan Range 402-425 Sentinel Totus 2 D-ERV Fan-Up to 0.59 m 3 /s (2,124m 3 /hr) Page 396-40 High Temperature Roof Fan (RDM)-up to 8.83m 3 /s (31,788m 3 /hr) Page 404-407 Sabre® Sickle Fan Assisted Roof Fairing (VSR )- up to 5.00m 3 /s (18,000m 3 /hr)) Pages 408-415 Francis house Top Fan (RMH)-up to 3.63m 3 /s (13,068m 3 /hr) Page 416-421 Lo-Carbon MX Roof Fan (MX)-up to 1.86m 3 /s (6,696 m 3 /hr) Page 422-425 Pages Air Treatment 426-435 Accessories and Controllers Non-residential 436-463 Slimline Range (SL)-up to 0.92m 3 /s (3,312m 3 /hr) Pages 428-4631 D1 Mini Direct Range-up to 2.25m 3 /s (8,100m 3 /hr) pages 432-435
Low-carbon residential fans continue our commitment to energy efficiency in this section, and you will find low-carbon solutions for intermittent and continuous fan applications. In axial or centrifugal, wall, ceiling or window applications in bathrooms or kitchens, we have a low-carbon fan that can save up to 90% of energy compared with the equivalent traditional fan. We are proud to be a market leader and continue to strive to provide you with the best products. Our latest product in this series is no exception-the new Lo-Carbon Revive has a lot of innovation and was developed specifically to meet the needs of the social housing market. The unique Multi-Vortex TM airflow technology ensures excellent pressure development and efficient and quiet operation. Revive’s Sense Smart TM technology makes the fan easy to install and provides a series of data through its easy-to-use interface. See page 24 for details.
NEW Lo-Carbon Svara Axial Bathroom/Toilet Fan 30 4 20 0.13 14-15 Lo-Carbon iQ Smart Axial Bathroom Fan 37-29-16-17 Lo-Carbon VA100 ® /SELV Axial Bathroom/Toilet Fan 21 7- 316 19 Lo-Carbon Silhouette ® 100/SELV Bathroom/Toilet Fan 30 8.7 38 0.30 20-21 Lo-Carbon Centra ® /SELV dMEV Unit 15 2.4 25.2 0.18 22-23 NEW Lo-Carbon Revive Kit/Filterless25athroom/ Lo-Carbon Solo Plus/SELV Centrifugal Bathroom/Toilet Fan 21 8.4 35.5 0.29 26-27 Lo-Carbon Minivent Duct Bath/Shower Fan Kit 31 6.5 23 0.21 28 Lo-Carbon LED Vent-A-light Duct Bath/Shower Fan Kit 6.5 23 0.21 29 Lo-Carbon Quadra ® /SELV Centrifugal Fan 63 38 50 0.60 30-31 Lo-Carbon Silhouette ® 125 Bathroom/Toilet Fan 44 8 37 0.18 32 Lo-Carbon VA150 56 30 30 30 30 30 36 Fan Lo-Carbon Silhouette ® 150 Axial kitchen fan 34-35
14 The introduction of Svara, the UK’s first application-controlled integrated fan, marked the birth of the next generation of integrated fans. For electricians, Svara’s Bluetooth application makes installation easy, allowing you to choose whether to choose intermittent or continuous ventilation; whether you want the humidistat to trigger the operation; and whether you need a timeout timer. No more cumbersome switches and jumpers! For consumers, Svara provides a higher level of comfort for their homes because it was developed to allow families to control their indoor air quality through apps. Aesthetics and silence The influence of the name Svara comes from the Swedish tradition of fans-a country known for iconic and thoughtful designs. Consumers will be attracted by Svara’s sleek and modern design, and noise is a key issue for consumers. Families will also be impressed by Svara’s quiet operation, which runs at only 17 dBA at low trickles. It is also easy to clean, because the central module disconnects the motor from the rest of the fan and only needs to be wiped with a soft cloth, and the energy-saving Svara with only 4W also has low power consumption. One model fits all Vent-Axia Svara that is programmed to handle most installations. The fan is set to work continuously at a trickle flow rate of 10l/s by default. When the fan senses someone in the room, it will increase the flow to 19l/s. If the humidity rises rapidly, such as in the shower, the fan will increase to the maximum flow rate at a speed of 30l/s. When the fan senses that the humidity level returns to normal, it will return to a trickle of 10l/s. If you need other settings or features, you can choose from the Vent-Axia Connect app, which can be downloaded from the App Store and Google Play. Functional light sensor When the light sensor is enabled, Svara will sense that someone is in the room and activate it. Its sophisticated light sensor is triggered by light movement and shadows. A delay can be set so that the fan will not be triggered by the light when the bathroom is quickly accessed at night. The light sensor can also distinguish the flashing of the headlights from the car and the room occupied, so it will not be triggered by passing cars and avoid nuisance operation. The sensitivity of the light sensor can be adjusted through the app. Over-limit timer The light sensor provides an over-limit timer, but only needs to be charged and neutral. In houses where only basic fans are installed, homeowners can upgrade to timed fans without rewiring. HumidistatSvara is equipped with a humidistat which can react to sudden changes in humidity, such as when someone is taking a bath. When set to continuous operation, once the humidity sensor is activated, the fan runs at a speed of 30l/s until the humidity returns to a normal level, and then the fan power is reduced to 10l/s. Changes in ambient humidity will not trigger the humidistat. The sensitivity of the humidity sensor can be changed through the app. The mute schedule and automatic loop mute schedule feature allows you to disable the enhanced features on Svara through the app, for example, this will prevent noise interference at night. In addition, during the holidays, you can set Svara in ventilation mode, which, depending on your choice, runs the purification function every 12 hours for 30, 60 or 90 minutes. However, if the light sensor detects that someone is in the room, Svara’s precise control will not clear it. New Lo-Carbon Svara • The UK’s first single fan controlled by an app! • Setting and control via the app via Bluetooth • Continuous or intermittent • 1 model suitable for all applications • Silent time scheduling and clear mode function • Smart light sensor with timeout timer-Allows replacement of the basic model fan • 3 speeds , IP44 protection level, DC motor 5-year warranty • Suitable for ceiling, panel or wall installation • Only 17 dBA
15 models of Svara kitchen and bathroom fans, 100 mm axial fans. The factory setting is continuous operation when the humidistat and light sensor/overrun timer are turned on. Model Stock Ref £Trade Lo-Carbon Svara 409802 205.09 Accessories Model Stock Ref £Trade Wall Kit 254102 21.55 Model Stock Ref £Trade Back Ventilation shutters 406605 19.46 Cover plate suitable for pipe sizes between Ø140-160mm Model cover plate Ref4107 £405 mm ) ABCDAB CØ DØ 60 21 99 177 Performance Guide Extraction Performance-FID (l/s) Sound dB(A) SFP (W/l/s) Low Trickle High Trickle Boost Max Watts @ 3m @ 0Pa 10 16 30 4 17- 20 0.13
16 Lo-Carbon iQ • Simple retro design to match the bathroom decoration • Extremely quiet-only 21 dB(A) • Really surface mountable with a detachable faucet • Smart control and control panel, easy to set up and adjust flexibly • Low Power consumption – only 5 W • Easy to clean and maintain • 5-year low-carbon motor warranty • Smart constant humidity control as standard • Innovative ventilation function to ensure good air quality • IP44 class market leading design With the Lo-Carbon iQ fan With the launch, we not only spent time to improve the operation and user experience of the fan, but also worked hard on the design. The result is a stylish fan whose surface is deeply eye-catching and matches the modern accessories in today’s bathrooms. The visible blades give a retro feel and help provide a very quiet noise level for the fan. Silent operation The open impeller and unique motor operation method provide more operating options, including silent continuous ventilation, adaptive speed control and flexible timer functions. Humidity control iQ has an intelligent fully automatic humidity sensor for humidity control. This means that the fan will only learn to operate when it has an impact on indoor air quality. The fan continuously monitors and records the moisture content to draw a map of the humidity distribution throughout the year. This process enables the fan to ensure that it can only operate when the fan can reduce the moisture content in the air. This reduces annoying operations. The fan also has two humidity control modes, mute or boost mode, which can be selected through the touch panel control. Control Panel Our goal is to allow end users to control and understand basic fan functions without having to read manuals. When the fan is connected to the power supply, it will also perform a self-test, that is, test all the status lights on the control panel and the function of the motor. Ideal for those who install to make sure everything is in order. Simple controls and LED feedback make commissioning and any readjustment can be done quickly and easily. LED feedback For many fans, it is difficult to understand the exact mode in which they operate. We have simplified this now to provide a visual indicator to see what the fan is doing and which mode is currently active. The fan uses three different colors on the visible status lights to accurately convey the operation it is performing. The blue light indicates that the fan is expelling moisture through the humidity sensor. The yellow light indicates that the timer is running. The purple light indicates that the automatic drying function has been activated. You choose the working mode of the fan. The intelligent overrun timer can be operated in many different ways. It can be used as a standard on/off or as an instantaneous switching time that automatically stops after overrun. You can use the control panel to easily set the required post-run time to 15 or 30 minutes, depending on your choice. The full-surface-mounted impeller and motor components are designed to be low-profile and easy to maintain. The socket on the fan can be completely removed. This design allows the fan to be installed on the wall without any sockets, so that it can be surface mounted. If your duct is less than 100 mm in size, or if the duct is bent directly from the back of the fan, but does not provide any depth for the socket, then this is an ideal feature. Cleaning and maintenance In order for the fans to effectively ventilate, keep them clean and the duct system and grille free of dust, which will reduce the air flowing through them, it is important. This is the first fan that can simply remove the impeller and open the center of the fan to freely enter the duct. Using the “outside swing” function, you can easily clean and remove fans, such as the grille that is blocked on the outer wall. Click the button to remove the impeller, then press the buckle and unscrew the motor-that’s it!
17 Automatic ventilation function The ventilation function means that when the fan does not work for 26 hours, it will run a 60-minute ventilation program to exchange the air in the bathroom. When you come back from vacation, you never have to worry about the sultry smell of mildew in the bathroom. Low-carbon 5-year warranty. Thanks to an integrated power adapter in the fan, we have been able to use a low-voltage motor with a service life of approximately 60,000 hours. This is about 3-5 times longer than a standard fan. The motor has extremely quiet bearings. By using low-voltage motors, we can significantly limit power consumption. The fan consumes only 5 watts, which is about one-third of the traditional AC bathroom fan. The model Lo-Carbon iQ Multi controls the fan, which can be operated in intermittent or continuous settings. Adjustable timer and humidity options, including integrated drawstring. Model stock Ref £Trade Lo-Carbon iQ 405155 205.09 The accessory leeward shutters are designed to reduce any incoming airflow when the fan is off. Model inventory Ref £Trade Leeward shutters 406605 19.46 Wall-mounted back panel is designed to cover the up mark. Previous fans have different footprints. 242 mm x 190 mm. Model Stock Ref £Trade Wall Mounting Backplane 406762 20.29 Dimensions (mm) DØ ABC ABC DØ 152 202 31 99/125 The product comes with a 30mm deep, 99mmØ and 125mm Ø performance extraction performance-FID Sound dB(A) Duct Ø trickle Flow/boost m 3 /hl/s @ 3m 100mm Max 108 30 28 100mm silent 72 20 21 100mm trickle 43.2 12 12 125mm Max 133.2 37 29 125mm silent 44515 100mm trickle 86.
18 Long Life Ventilation VA100 Vent-Axia Lo-Carbon VA100 series uses low-carbon long-life DC motors, which are more efficient than traditional motors and can save up to 87% of energy. The Vent-Axia Lo-Carbon VA100 series of shutters are equipped with an electric shutter mechanism, which requires no additional power when operating or closing. Installation Lo-Carbon VA100 is a 100 mm axial flow fan, equipped with overall protection for low-energy lighting circuits, suitable for bathrooms or toilets. VA100 can be used with easy-wire in one line terminals quickly and simply. Suitable for installation in windows, walls or panels/ceilings using available kits. The 100 mm telescoping wall kit is suitable for 225 to 360 mm thick walls. This series complies with the current building regulations for LT, XT and HTP models of internal room ventilation of 6 liters/sec, bathroom 15 liters/sec, and 15-minute timeout timers. Safety Extra Low Voltage (SELV) Fan Safety Extra Low Voltage (SELV) is designed for use in areas where fans must be installed in Zone 1 containing a fixed bathtub or shower according to the IEE wiring regulations. VA100 SELV can be safely installed in the spraying area. The fan has an IPX7 degree of protection and is controlled by the enclosed power safety isolation transformer with 12V DC SELV output, which is far away from any spray source and cannot be reached by people using a fixed bathtub or shower. Model Lo-Carbon VA100 LP/SELV LP (Pullcord) Ultra-long life DC motor. Pull cord on/off override switch with indicator light. 2 speed options. Model inventory reference £Trade LP 443159 61.69 SELV LP 441614 131.21 Lo-Carbon VA100 XP/SELV XP (shutter/pull cord) ultra-long life DC motor. Pull rope and on/off override switch with indicator light. 2 speed options. Model inventory reference £Trade XP 443160 84.98 SELV XP 459049 144.70 Lo-Carbon VA100 LT/SELV LT (timer) electronic adjustable overrun timer (5-30 minutes). Indicator light. 2 speed options. Model inventory reference £Trade LT 443161 76.22 SELV LT 441615 140.36 Lo-Carbon VA100 XT/SELV XT (shutter/timer) integrated electronic adjustable overrun timer (5-30 minutes). Indicator light. 2 speed options. Model inventory Ref £Trade XT 443162 112.41 SELV XT 459050 171.93 Lo-Carbon VA100 LHTP/SELV LHTP (Integrated Humidity Sensor/Drawstring/Timer) completes the integrated humidity control with drawstring covering. The indicator lamp is operated only on manual operation. 2 speed options. Model inventory Ref £Trade LHTP 443163 195.76 SELV LHTP 441616 225.81 Lo-Carbon VA100 XHTP/SELV XHTP (blinds/integrated humidity sensor/draw cord/timer) is equipped with an integrated humidity control with draw cord covering. The indicator lamp is operated only on manual operation. IPX4 rating. 2 speed options. Model stock Ref £Trade XHTP 443164 208.69 SELV XHTP 436064 240.15 Lo-Carbon VA100/SELV • Complies with current building regulations and approval documents F & L • Suitable for wall, ceiling, panel and window installation • Equipped with electric shutters • For low-energy lighting circuits Provides protection • IPX4 rating-IPX7 rating (SELV) • High-efficiency long-life DC motor with 5-year warranty • Energy consumption reduced by 87% • Low noise • One of two speeds can be selected during installation • Low specific fan power • Daily Recorder as standard configuration for all models
19 Accessories Wall Mounting Kit Fixing Hole Diameter 117mmØ Model Stock Ref £Trade Wall Mounting Kit White 254102 21.55 Wall Mounting Kit Brown 254100 21.55 Window Kit Fixing Hole Diameter 105mmØ Model Stock Ref £Trade Window Kit 254101 21.55 Tamper-proof AA 44323 Window Kit Ø 44323 3 3 2 3 3 2 3 3 2 3 3 2 3 3mm EFGHH panel wall window ABC DØ EFGH bathroom/toilet 146 47 53 98 31 31 74 200 SELV transformer (width x height x depth) 87 x 87 x 33 weight 1kg performance extraction performance-FID sound dB(A) SFP (W/l/ s) Area model m 3 /hl/s Watts @ 3m @ 0Pa Low-carbon bathroom VA100/SELV LP/XP/LHTP/XHTP/LT/XT 60 17 3.4 32 0.20 Low-carbon bathroom VA100/SELV LP/XP/LHTP /XHTP/LT/XT 74 21 7.0 36 0.33
20 Lo-Carbon Silhouette 100/SELV • Model basic/timer/humidity and timer • Low power consumption-reduce operating cost • Fully open and close opaque blinds-improve insulation and privacy Choose 1 of 2 speeds during installation • Blue power indicator light (except B model)-modern aesthetics • Ball bearing motor for vertical or horizontal applications • Unique humidity sensor track-improved response • 5-year motor warranty • IPX4 rating-IPX7 rating (SELV) • Suitable for wall, ceiling, panel and window installation. Ultra-thin bathroom ventilation. With an ultra-thin shape of only 17 mm, the low-carbon silhouette blends with the wall to provide unobtrusive installation. The FID performance of Lo-Carbon Silhouette is as high as 30l/s. It can be installed on the ceiling/panel and connected to appropriate ducts leading to the outside. Safety Extra Low Voltage (SELV) Fan Safety Extra Low Voltage (SELV) is designed for use in areas where fans must be installed in Zone 1 containing a fixed bathtub or shower according to the IEE wiring regulations. Silhouette SELV can be safely installed in the spraying area. The fan has an IPX7 degree of protection and is controlled by the enclosed power safety isolation transformer with 12V DC SELV output, which is far away from any spray source and cannot be reached by people using a fixed bathtub or shower. SELV transformer conforming to BS EN 60742. Model Lo-Carbon Silhouette 100B/SELV 100SVB100mm bathroom/toilet fan with leeward shutters. Model inventory reference £Trade 100B 441624 61.04 SELV 100SVB 441511 118/SELV10SVB100S LV10Carbon10Carbon10TLV10Carbon10 Time / with integrated adjustable electronic overflow timer (5-30 minutes), toilet fan and leeward blinds with indicator lights running only on manual operation. Model stock reference £Trade 100T 441625 76.28 SELV 100SVT 441512 144.95 Lo-Carbon Silhouette 100HT (Humidistat/Timer) 100mm bathroom/toilet fan with adjustable automatic humidity sensor from 60-90% RH and over-limit timer , Indicator lights, operate only during manual operation, and rear ventilation shutters. The data logger is the standard configuration of all Silhouette fans with Lo-Carbon humidity control. Model inventory Ref £Trade 100HT 441626 126.64 Lo-Carbon Silhouette 100H SELV (humidifier) ​​100 mm bathroom/toilet fan, with 60-90% RH environmental response humidity sensor, indicator light for manual operation and leeward wind Shutters. Safety ultra-low voltage version. Model stock reference £Trade SELV 100SVH 441513 195.27 Accessories wall mount kit fixing hole diameter 117mmØ Model stock reference £Trade Wall mount kit white 254102 21.55 Wall mount kit brown 254100 21.55 Window kit fixing hole diameter 44mm diameter 117mmØ Model stock Ref 23.32 17mm actual outline
21 Dimensions (mm) Panel Wall Mounting Kit AA ØB CDEFE A BØ CDEF 160 99 115 132 200 32 SELV Transformer (WXHXD) 87 X 87 X 33 Weight 0.6kg Performance Guide 0 5 10 15 20 25 3 0 5 Air volume/s Pressure Pa 30 35 25 35 1 2 Extraction performance-FID sound dB(A) SFP (W/l/s) Area model curve reference m 3 /hl/s Watts @ 3m @ 0Pa Toilet low-carbon silhouette 100 B/ T/HT/SVB /SVT/SVH 1 60 17 3.4 34 0.20 Bathroom 2 108 30 8.7 38 0.30 Window installation: blinds cannot be used and must be removed
22 Lo-Carbon Centra/SELV • Complies with building code approval documents F and L, system 3 continuous mechanical extraction • Approved in SAP PCDB-low SFP • Discreet and elegant shape • IPX4 class-IPX7 class (SELV) • dMEV pressure Testing equipment • 5-year motor warranty • Suitable for wall, ceiling, panel and window installations • SELV models are equipped with remote transformers and are suitable for “Zone 1″ What is distributed MEV (dMEV)? The building code approval document F gives examples of four main ventilation methods. System 3, continuous mechanical exhaust ventilation, can use a single centralized exhaust device (such as Sentinel Multivent pipe to “wet” room (kitchen, bathroom, suite and toilet) or scattered personal fans, such as Lo- “wet” room Carbon center. The fan runs continuously at a level close to silent, providing a simple and effective form of ventilation. SELV (Safety Extra Low Voltage) is designed to be used in areas where a fixed bathtub or shower fan can be installed in area 1. Entrance Protection (IP) to IPX7 Lo-Carbon Centra SELV can be safely installed in the spraying area. The independent transformer can be installed away from the spray area and the bathtub or shower. Lo-Carbon Centra complies with the building code approval document F for all The latest requirements for ventilation in housing systems, all models are provided with a 5-year motor warranty. Two trickle flow rates (6l/s or 9l/s) can be selected through a simple “jump” on the control panel. From simple live switching to integrated constant Humidifier, you can use different methods to operate the booster speed of 15 l/s. For more information, please refer to the individual models. The charming and discreet styling of the Vent-Axia Lo-Carbon Centra will complement the decoration of any new home, and almost Silent operation ensures optimal ventilation without intrusive noise. The specific fan power dMEV version identified in SAP PCDB. The specific fan power of Lo-Carbon Centra in through-wall kitchen applications is only 0.18 W/l /s. Model Lo-Carbon Centra dMEV automatically selects the speed during installation and is suitable for bathrooms or kitchens. The integrated air pressure sensor checks the airflow during the first installation and also helps the fan to compensate for external wind pressure. Stock Ref £Trade 441782 123.19 Lo -Carbon Centra T/SELV T (timer) is suitable for bathroom and toilet applications. The device runs continuously under trickle setting and can be enhanced by activating the switch real-time input of the timer (fixed on T for 15 minutes) model, Adjustable for 5-30 minutes on SELV models. Model inventory reference £Trade T 442954 139.62 SELV T 443175 171.28 Lo-Carbon Centra TP/SELV TP (Timer/Drawstring) For bathroom/toilet applications, the continuous running TP model is available Lift through the drawstring that starts the timer (TP model is fixed for 15 minutes, SELV model can be adjusted for 5-30 minutes). Model inventory reference £Trade TP 44712​​7 156.68 SELV TP 44712​​8 187.67 Lo-Carbon Centra HT/SELV HT (constant Humidifier/Timer) For bathroom/toilet applications, continuously running HT models are automatically enhanced by real-time input from a built-in humidistat or a switch that activates the timer (HP models are fixed for 15 minutes, SELV models are adjustable for 5-30 minutes). Model Stock Ref £Trade HT 442955 182.51 SELV HT 443176 214.44 Lo-Carbon Centra HTP/SELV HTP (humidifier/timer/rope) For bathroom/toilet applications, the continuously running HTP model is activated by the built-in humidistat automatically lifted The chronograph drawstring (HTP model is fixed at 15 minutes, SELV model is adjustable for 5-30 minutes). Model stock Ref £Trade HTP 443045 182.51 SELV HTP 443177 214.44 WINNER 2011 Energy Efficiency Initiative Award winner, our low-carbon continuous ventilation product series
23 Accessory model inventory reference £Trade 150 mm conversion kit 443334 28.65 wall mount kit white 254102 21.55 wall mount kit brown 254100 21.55 window kit 442947 23.32 ceiling kit 443800 15.80 15.84 model 15.84 LoABC type 1055 type LBC 1035 type LBCV 105 type ABC size 99 Lo-Carbon Centra T/TP/HT/HTP 160 35 80 99 Transformer 87 x 87 x 33mm (W x H x D) (SELV models only) Performance Guide Extraction performance (l/s) Power consumption (Watts) Sound dB (A)@ 3m Trickle Trickle Trickle Trickle Trickle Model Low High Boost Low High Boost Low High Boost Lo-Carbon Centra dMEV/All SELV 6 9 15 1.4 1.6 2.4 10.8 15.5 25.2 Lo-Carbon Centra T/TP/HT/HTP 6 9 15 3.2 3.5 4.2 10.8 15.5 25.2 SAP PCDB performance (dMEV model) system only install rigid duct system unit configuration position fan speed set flow rate (l/s) SFP (W/l/s) indoor (duct) kitchen height 13.2 0.32 indoor (duct type) wet Room 9 l/s 8.4 0.28 Through the wall kitchen height 13.5 0.18 Through the wall wet room 9 l/s 8.6 0.20 System with F flexible or mixed duct system only installation unit configuration position fan speed set flow rate (l/s) SFP (W/l /s) Indoor (pipe) kitchen height 13.2 0.37 Indoor (pipe) wet room 9 l/s 8.6 0.31 Through wall kitchen height 13.5 0.18 Through wall wet room 9 l/s 8.6 0.20
24 New Lo-Carbon Revive/SELV • Designed for social housing • Continuously operating bathroom and kitchen fans • Air extraction up to 60 l/s • Easy-to-read LED display for debugging and data collection • Intelligent Smart Sense TM Technology tells you how many days to run, accelerate operation, and consume energy • Innovative Multi-Vortex technology ensures high performance but low sound and energy levels • 5 or 7 year warranty options • Small footprint, optional decorative frame designed specifically for social housing Smart Lo-Carbon Revive is a new product filterless integrated fan designed to meet the specific needs of social housing. Revive has powerful, quiet, and efficient ventilation, providing residents with good indoor air quality and comfort, while being quick to install, easy to maintain, low maintenance, and reliable. Smart Sense TM technology adopts Smart Sense TM intelligent technology Revive’s simple alphanumeric LED display is clear and easy to read, and has a three-button menu for debugging and data collection, so installation is quick and convenient. Smart Sense™ technology will even tell the LED display which direction to use depending on whether it is wall-mounted or ceiling-mounted. All of this saves on-site time and reduces installation complexity. The display screen also displays real-time data, so the landlord can assure residents of low operating costs. This includes data such as operating days, trickle or accelerated operating hours, and more specifically, the accelerated operating hours triggered by the humidity sensor. Revive can also tell you how much energy the fan uses. Multi-Vortex TM technology Revive has low maintenance costs because its market-leading Multi-Vortex TM technology does not require a filter, and the highly sculpted interior is actively dust-proof and avoids clogging, thereby helping to avoid callbacks. In addition, Multi-Vortex TM technology has a powerful, efficient and quiet high-pressure mixing impeller-to meet all the needs of social housing residents. A variety of configuration options Revive can draw up to 60l/s flow from the kitchen, but during installation, you can choose to change the settings to allow installation in the bathroom. The installer can also choose the duct mode or through the wall mode. All selections are made via the intuitive LED display. Model Lo-Carbon Revive 7/SELV 7HTP Continuous operation fan, with kitchen or bathroom settings, can be selected from 9, 15, 30 and 60l/s combination of trickle and boost speed. Daily recorder and power running table are included as standard equipment. 7-year warranty. Adjustable dynamic environmental response humidity sensor. The timer can be adjusted from 1 to 30 minutes. Built-in booster activated by pull cord, humidity sensor, switched real-time or remote button. The front of the tile is easy to install. Model Stock Ref £Trade Lo-Carbon Revive 7 473848 328.39 Lo-Carbon Revive SELV 7 473849 377.29 377.29 Lo-Carbon Revive 5/SELV 5HTP continuous operation fan, with kitchen or bathroom settings, combined with trickle and pressurization speed can be from 9, Choose from 15, 30 and 60l/s. Daily recorder and power running table are included as standard equipment. 5-year warranty. Adjustable dynamic environmental response humidity sensor. The timer can be adjusted from 1 to 30 minutes. Built-in booster activated by pull cord, humidity sensor, switched real-time or remote button. Open front grille. Model inventory reference £Trade Lo-Carbon Revive 5 473850 278.78 Lo-Carbon Revive SELV 5 473851 357.05 Lo-Carbon Revive/SELV HTP Continuous operation fan, with kitchen or bathroom settings, optional combination of trickle and boost speed 9, 15, 30 and 60 liters/sec. 5-year warranty. Adjustable dynamic environmental response humidity sensor. The timer can be adjusted from 1 to 30 minutes. Built-in boost activation
25 Through the pull cord, humidity sensor, switch on-site or remote control button. Open front grille. Model inventory reference £Trade Lo-Carbon Revive 473852 237.56 Lo-Carbon Revive SELV 473853 310.45 Accessory model inventory reference £Trade Wall Kit White 254102 21.55 Wall Kit Brown 254100 21.5861072 Ceiling kit 48072 Ceiling kit 4807277277777 Ceiling kit decorative frame 474041 11.00 Dimensions (mm) DBA CØ DAB CØ D 30 132/102 99 193 Closed/open grille decorative frame size (mm) ACABABC 259 191 10 Performance guide pressure su er P a Low kitchen volume flow high Kitchen Boost Low Trickle Bathroom Boost 0 20 40 60 80 100 120 140 160 0 10 20 30 40 50 60 1 1 2 2 3 3 4 4 Extract Performance (l/s) Power Consumption (Watts) Boost Model Trickle Low Kitchen Supercharged Revive 9 15 30 60 1.4 2 6 26
26 Lo-Carbon Solo Plus/SELV • Energy saving up to 70% • Standard no filter-Innovative impeller design means no filter required • 5 years low carbon motor guarantee • Compliant with current building regulations approval documents F & L • IPX4 rating-IPX7 Class (SELV) • Can be flush or surface mounted, with adjustable rear or side outlet taps • SELV models are suitable for installation above showers or bathtubs or within reach • Very low sound level • Suitable for walls , Ceiling and Panel Mounting • SELV Model-Vent-Axia’s Lo-Carbon Solo Plus series with long-life ventilation with remote transformer is designed for wall and duct applications, suitable for internal bathrooms, toilets and other small rooms. Lo-Carbon Solo Plus has a white finish and can be flush-mounted or surface-mounted, with two 100 mm circular sockets for rear entry or connection to a vertical piping system. The powerful centrifugal impeller allows installation using 100 mm pipes in straight-line operation, while still achieving the 15l/s required by the building code approval document F. Products that operate continuously, such as Lo-Carbon Solo Plus, are classified as a whole-house ventilation system installed in all humid areas of the residence, so only the air volume listed in Table 5.1a and 5.1b of the building code approval document F needs to be moved. Wall or pipe setting for boost/override operation to meet building codes, thereby ensuring the lowest energy usage and low noise levels. All models have optional constant trickle ventilation speed (12l/s), which can be selected during installation. Depending on the model, the fan will switch from trickle (if selected) to boost via the drawstring/light switch/humidity sensor/PIR. All models can be installed on walls, panels or ceilings, and can be connected to round, rectangular or Vent-Axia flat ducts. The housing of the electrical components is made of flame-retardant materials. Safety Extra Low Voltage Fan (SELV) According to IEE wiring regulations (BS 7671), Lo-Carbon Solo Plus SELV fans are designed to be used in areas where fans must be installed above or in Zone 1 of rooms containing fixed bathtubs or showers. Install in the spray area. The protection level of the fan is IPX7. Control is carried out by the enclosed power safety isolation transformer device with 12V DC SELV output, which is far away from any spray source and cannot be reached by people using a fixed bathtub or shower. The controller power supply voltage is 220-240V/1/50Hz. Output to fan SELV 12V DC. Model Lo-Carbon Solo Plus P/SELV P (pull cord) flush or surface mount. Controlled by a drawstring. 2 Speed. Constant trickle option. Adjustable boost. Built-in low-carbon controller. Model stock Ref £Trade P 427481 151.04 SELV P 427485 160.21 Lo-Carbon Solo Plus T/SELV T (timer) flush or surface mount. Controlled by room lights or switches. 2 Speed. Constant trickle option. Adjustable boost. Adjustable timer overflow. Delay timer. Built-in Lo-Carbon controller. Model Stock Ref £Trade T 427482 173.05 SELV T 427486 183.08 Lo-Carbon Solo Plus HT/SELV HT (humidifier/timer) flush or surface mount. Humidity control fan with over-control drawstring. Constant trickle option. Adjustable boost. Adjustable timer overflow. Delay timer. Adjustable humidity sensor. Built-in low-carbon controller. The data logger is the standard configuration of all Lo-Carbon humidity control Solo Plus fans. Model stock Ref Trade HT 427483 244.09 SELV HT 427487 251.75 Lo-Carbon Solo Plus TM/SELV TM (Timer/PIR) Flush or surface mount. Controlled by the integrated PIR detector. 2 Speed. Constant trickle option. Adjustable boost. Built-in low-carbon controller. Model stock reference £Trade TM 427484 343.28 SELV TM 427488 350.90
27 Dimensions (mm) BDCAEFHIJG ABCD EØ FGHIJ 263 224 106 55 98 62 65 98 21 34 Weight 2.2kg, SELV weight 2.7kg. Dimensions: (width x height x depth) 87x87x33mm. Performance Guide (Pipeline Mode) 1 2 3 0 20 40 60 80 100 120 0 5 10 15 20 25 Pressure Pressure Volume Flow l/s Boost Low Trickle High Trickle 1 2 3 Extract Performance l/s (m 3 / h) Power consumption -Watts dB(A) @ 3m SFP (W/l/s) model Boost High Trickle Low Trickle Boost High Trickle Low Trickle Boost High Trickle Low Trickle @ 0Pa Lo-Carbon Solo Plus/SELV P/T/HT /TM wall mount mode 18 (64.8) 12 (43.2) 8 (28.8) 6 2.9 2.3 33.5 27 23.5 0.28 Pipeline mode 21 (75.6) 17 (61.2) 11 (39.6) 8.4 5.325 6 VAC 4 5.32 3 5 Hz 5 when testing Lo-Carbon Solo Plus Bezel is used for flush installation-reducing the need for patching. Model Stock Ref Trade Bezel 404106 11.89 Model Stock Ref Trade Wall Kit White 254102 21.55 Wall Kit Brown 254100 21.55 Filter pack (1 per pack) The design of Lo-Carbon Solo Plus means that it does not require a filter. However, if you want to install the product in a greasy environment, you may need to install a filter to protect the product. Model stock reference £Trade filter package 449265 5.88
28 Powerful low-carbon in-line fan kit Vent-Axia Lo-Carbon Minivent Duct Bath/Shower kit includes all the components needed to install a 100 mm duct system. This simplifies the process of installing efficient ventilation systems into small rooms (including bathrooms, showers and toilets). It is especially suitable for en suite bathrooms. After installing the Lo-Carbon Minivent shower kit, the fan kit has sufficient performance to meet the building code requirements for toilets and bathrooms. The timer version should be used for internal rooms. The kit includes a Lo-Carbon Minivent in-line fan, a white ceiling grille and faucet, a 3-meter flexible duct, and an external shutter for soffit or wall mounting. The pipe should be cut to the required length and the bend radius should be kept to the maximum to provide the best fan performance. Enclosed junction box, category 2 equipment. The power supply voltage is 220-240/1/50Hz. Model Lo-Carbon Minivent Shower Fan (Basic) includes-high output duct fan, 3 meter long flexible duct, ceiling entrance grille and faucet, soffit/wall exit grille. Model inventory Ref £Trade Basic 441421 62.04 Lo-Carbon Minivent Shower Fan (timer) includes-high output duct fan, 3 meter long flexible duct, ceiling entrance grille and faucet, soffit/wall exit grille. Model inventory reference £Trade Timer 441422 74.76 Dimensions (mm) AB Rear view C DØ E Side view ABC DØ E 130 155 90 98 27 Internal/external grid size 140x140mm Transformer (W x H x D) 87 x 87 x 33 Performance Guide Extraction performance-FID sound dB(A) SFP (W/l/s) Model m 3 /hl/s Watt @ 3m @ 0Pa Lo-Carbon Minivent B/T 110 31 6.5 23 0.21 Lo-Carbon Minivent • Complete kit available • Meet the requirements of building code approval documents F & L for maximum 1.5m pipes and 1x 90° bends in toilets and bathrooms • Adjustable timer version available • 5-year motor warranty • 1 of 2 speeds can be selected during installation
29 100mm Lo-Carbon axial in-line shower fan and light kit. Provide synchronized fan and light operation. Suitable for shower rooms and wet areas. Provide white and chrome frame on the lamp assembly. Fixing clips or screws can be used to fix the lamp assembly in place. The typical specification CE marking complies with all relevant EEC harmonized directives. The fan is double insulated, and the motor is equipped with a thermal protection device. Lightweight assembly class III. Electric 12V DC 3W GU5.3 sealed lamp. Powered by the LED driver. LED lamp lumen output 180lm-200lm input, AC. Output-12 volts DC. 1A. Model Lo-Carbon Vent-A-Light fan and LED light kit (basic) 100mm axial flow shower fan and light kit. Including fan, 3m flexible duct, white grille, LED lamp transformer and lamp assembly with white and chrome frame. Model inventory reference £Trade Basic 441423 129.68 Lo-Carbon Vent-A-Light fan and LED light kit (timer) 100 mm axial line shower fan and light kit. The fan has an electronic overrun timer that can be adjusted from 5 to 30 minutes. The factory setting is 15 minutes. Including fan, 3m flexible duct, white grille, LED lamp transformer and lamp assembly with white and chrome frame. Model Stock Ref £Trade Timer 441424 144.95 Dimensions (mm) E Side view rear view DØ ABC GH Ø FABC DØ E FØ G HØ 130 155 90 98 27 140 74 98 Internal/external grid size 140x8F x 140 mm x 140 mm x 87 x 33 Performance Guide Extraction performance-FID Fan Watts Light Watts Sound dB(A) @ 3m SFP (W/l/s) @ 0Pa Model m 3 /hl/s Lo-Carbon Vent-A-Light B/T 110 31 6.5 3 23 0.21 Tested under 240V 50Hz Lo-Carbon LED Vent-A-Light • Suitable for shower rooms and damp areas • Now equipped with 3W LED lights • Provide fans and lights running at the same time • Comply with the current building regulations and approval documents F & L • Can be installed Choose 1 of 2 speeds • Double insulated fan • Lightweight component class III • 5 year motor warranty • White and chrome frame available
30 Lo-Carbon Quadra/SELV • Complies with F & L documents approved by current building regulations, can be used intermittently or continuously • Approved in SAP PCDB-Low SFP 0.38 W/l/s on PCDB • 100 mm round socket, Easy to install and replace any existing fan-flush or surface mount • No filter technology and maintenance-free • Low-carbon motor provides 90% energy saving and long life • Motor cartridge cartridge for easy replacement • Integrated daily recorder (SELV model Options) • 5-year motor warranty • IPX4 rating-IPX7 rating (SELV) • Suitable for wall, ceiling and panel installation of any room ventilation Lo-Carbon Quadra provides a single fan suitable for surface or embedded installation. The low speed can be selected between 6, 9 and 12l/s, and the high speed can be selected between 15, 30 and 60l/s. All of these have the choice of wall or two pipes to ensure that the installation performance is met. Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV is designed to meet architectural requirements. According to the IEE wiring regulations, this area needs to be installed in Zone 1 containing a fixed bathtub or shower. Lo-Carbon Quadra SELV can be safely installed in the spraying area. The 24VDC safety isolation power supply is located far away from the spraying area and out of the reach of the people using the facility. Discrete Due to the precisely balanced impeller, it has discrete aesthetics and low noise levels, and it is also one of the least conspicuous centrifugal kitchen fans. The front cover design also does not provide an area for dirt to accumulate, so it looks more durable. Model Lo-Carbon Quadra TP/SVTP (timer/rope) dual speed: continuous operation or intermittent to high speed. High-speed (on/off) or real-time switch (with timeout timer) by pulling the rope. Model stock Ref £Trade TP 439251 244.69 SVTP 442865 281.39 SVTP data logger 446269 319.76 Lo-Carbon Quadra HTP/SVHTP (humidifier/timer/rope) two-speed: continuous operation or intermittent to high speed. High speed is achieved through integrated drawstring (on/off), integrated adjustable humidity sensor or live switch (with timeout timer). When the humidity sensor is triggered, the flow rate is increased to 50% of the set Boost speed in proportion to %RH. Model inventory reference £Trade HTP 439181 287.14 SVHTP 442866 329.37 SVHTP data logger 446270 367.76 Lo-Carbon QuadraTM/rP Speed: continuous operation or intermittent high-speed operation. High speed is achieved through integrated PIR sensor or real-time switch (both with overrun timer). Model inventory reference £Trade TM 439253 338.24 SVTM 442867 388.61 Accessory model inventory reference £Trade Embedded mounting kit 439256 14.33 Filter (optional) 439164207 Wall mounting kit 59 59 Frame kit white 254102 21.55 Wall mounting kit brown 254100 21.55 WINNER 2011 Energy Winner of the Efficiency Initiative Award, our series of low-carbon continuous ventilation products.
31 Dimensions (mm) ACFD EØ BHG Rear view Front view Side view A BCD EØ FGH 230 260 112 67 98 27 58 79 Performance guide 1 2 3 6 l/s 9 l/s 12 l/s 4 5 6 15 l/s 30 l/s 63 l/s 0 50 100 150 200 250 300 0 10 20 30 40 50 60 70 Volume (l/s) Pressure (P a) 4 5 6 Boosting speed volume (l/s) Pressure (P a ) 0 10 5 15 20 0 10 15 5 20 3 2 1 Continuous trickle speed extraction performance power sound level dB(A) @ 3m SEC model m 3 /hl/sm 3 /hl/s Watt level Lo- Carbon Quadra /SELV TP/ HTP/ TM 227 63 22 6 38 3.8 50 20 D FID performance. Through-wall installation test SAP PCDB Performance Systems with Rigid Ductwork Installation Only Unit Configuration Location Fan Speed ​​Setting Flow Rate (l/s) SFP (W/l/s) In Room Kitchen 15 l/s 15.8 0.41 In Room Wet Room 9 l/ s 14.6 0.61 Through-the-wall kitchen 15 l/s 21.4 0.38 Through-the-wall wet room 9 l/s 19.5 0.50 The system only installs flexible or mixed duct system unit configuration position fan speed setting flow (l/s) SFP (W/l / s) Indoor kitchen 15 l/s 13.7 0.41 Indoor wet room 9 l/s 12.9 0.63 Wall kitchen 15 l/s 21.4 0.38 Wall wet room 9 l/s 19.5 0.50
32 Lo-Carbon Silhouette 125 • Basic model/timer/humidity and timer • Low power consumption-lower operating cost • Quiet operation • Fully open and close non-transparent shutters-Improve insulation and privacy • Two options for installation 1 in speed • IPX4 rating • Ball bearing motor for vertical or horizontal applications • Unique humidity sensor track-improved response • 5-year motor warranty Ultra-thin shape, low-carbon silhouette and wall to provide unobtrusive installation. The FID performance of Lo-Carbon Silhouette is up to 160m 3 /h. It can be installed on the ceiling/panel and connected to appropriate ducts leading to the outside. Model Lo-Carbon Silhouette 125B 125mm bathroom/toilet fan with indicator light and leeward shutters. Model inventory reference £Trade 125B 446483 118.99 Lo-Carbon Silhouette 125T (timer) 125mm bathroom/toilet fan, with integrated adjustable electronic timeout timer (5-30 minutes), indicator light, operated only on manual operation, and Leeward shutters. Model inventory reference £Trade 125T 446484 134.26 Lo-Carbon Silhouette 125HT (humidifier/timer) 125mm bathroom/toilet fan, with 60-90 integral adjustable automatic humidity sensor% RH and over-limit timer, only in Indicator light and retreat air door running under manual override. The data logger is the standard configuration of all Silhouette fans with Lo-Carbon humidity control. Model Stock Ref £Trade 125HT 446485 225.23 Accessories Model Stock Ref £Trade Wall Mounting Kit 455226 24.43 Dimensions (mm) Panel A BØ CDAA BØ CD 187 125 131 149 Performance Guide 0 0 5 10 15 Pressure 205 Pa 205 45 40 20 15 5 10 1 2 Curve Ref Extract Performance Sound dB(A) @ 3m SFP (W/l/s) @ 0Pa Model m 3 /hl/s Watts Lo-Carbon Silhouette 125B/T/HT Low 1 120 33 4.5 33 0.14 High 2 160 44 8 37 0.18
33 Long Life Ventilation Vent-Axia Lo-Carbon VA150 fan adopts Lo-Carbon long-life DC energy-saving motor, the service life is 5 times longer than the traditional motor, and the energy saving is up to 60%. The extended service life of Lo-Carbon fans is due to the use of a new generation of high-quality electronically controlled ball bearing motors specially developed for this series. The motor is specially designed for the humid environment of the utility room and the kitchen, which can discharge the old and humid air quietly and efficiently. The Vent-Axia Lo-Carbon VA150 series of shutters are equipped with an electric shutter mechanism, which requires no additional power when operating or closing. Installation Lo-Carbon VA150 series is suitable for installation in panels, walls or windows using available kits. Lo-Carbon fans use reversible grommets and easy-to-connect terminals to install quickly and easily, and are suitable for installation on walls or ceilings at any angle. The 150mm telescopic wall kit is available with white or brown exterior grille. The kit comes with a retractable wall sleeve to fit 225-360 mm thick walls. The aperture is 152mm. The window accessory kit can be used for all Lo-Carbon 150mm models, through single or double-glazed windows up to 40mm thick. The aperture is 152mm. Model Lo-Carbon VA150P (Shutter/Pullcord) Ultra-long life DC energy-saving motor. Equipped with electric shutters. It is controlled by the rope on/off switch. Model stock Ref £Trade VA150P 459123 205.61 Lo-Carbon VA150T (shutter/timer) ultra-long life DC energy-saving motor. Equipped with electric shutters. It is controlled by an integrated power supply with an electronically adjustable overrun timer (5-30 minutes). Model inventory reference £Trade VA150T 459124 253.59 Lo-Carbon VA150HP (shutter / humidistat) ultra-long life DC energy-saving motor. Equipped with electric shutters. It is controlled by an integrated power supply with a rope override switch and an adjustable humidity sensor (60-95% RH). Model inventory reference £Trade VA150HP 459 125 313.27 Accessories model inventory reference £Trade Wall mount kit white 140902 24.70 Wall mount kit brown 140903 24.70 Window kit 12.70 Size 12 (mm) BAAEC DØ GHIFF Panel Wall Window ABC DØ EFGHI 216 224 80 146 60 220 37 55 104 Weight 1.2kg Performance Guide Extract Performance Sound dB(A) SFP (W/l/s) Model setting m 3 /hl/s @ 3m Watts @ 0Pa Lo-Carbon VA150P/T/HP Utility 160 46 33 7.5 0.16 Kitchen 230 64 36 11.5 0.18 Lo-Carbon VA150 • Reduce the carbon footprint of the family • Long-life low-carbon motors 5 times longer life than traditional motors • Energy saving up to 60% • Compliant with current building regulations and approval documents F & L during installation • IP44 rating • Low noise level • 5-year motor warranty • Suitable for wall, ceiling, window and panel installation • Equipped with electric shutters • 1 can choose 2 speeds for installation
34 Lo-Carbon Silhouette 150 • Stylish ultra-thin grille • Downstream airflow guide vanes to improve pressure development • Ball bearing motors for vertical or horizontal applications • Wall-mounted kit design meets the requirements of building code approval document F • 5-year motor Warranty • 1 of 2 speed can be selected for installation • IPX4 rating • Low specific fan power • Suitable for wall, ceiling and panel installation Ultra-thin low-carbon kitchen ventilation Lo-Carbon Silhouette 150 series are designed for modern life. The profile of Lo-Carbon Silhouette on the kitchen model is only 19 mm, which blends with the wall to provide unobtrusive installation. Installed in the center of the fan, under the ultra-thin grille is an electronic device, which contains a humidistat (HT model) to detect changes in internal humidity or a timeout timer option that can be adjusted between 5 and 30 minutes . FID performance is 65l/s, double insulation. The power consumption is only 9 watts. Model Lo-Carbon Silhouette 150B 150mm kitchen fan with indicator light and leeward shutters. Model stock Ref £Trade 150B 441628 119.46 Lo-Carbon Silhouette 150T (timer) 150mm kitchen fan, with integrated adjustable electronic overrun timer (5-30 minutes), indicator light only runs on manual operation and rebound blinds . Model stock Ref £ Trade 150T 441629 134.26 Lo-Carbon Silhouette 150HT (humidifier/timer) 150mm with integrated adjustable automatic humidity sensor, from 60-90% RH and over-limit timer, indicator light only in manual operation and after Run on the ventilation shutters. The data logger is the standard configuration of all Silhouette fans with Lo-Carbon humidity control. Model Stock Ref £Trade 150HT 441630 237.40 Accessories Model Stock Ref £Trade Wall mount kit white 140902 24.70 Wall mount kit brown 140903 24.70 Dimensions (mm) ADC Ø BAGHGA BØ CDGH 223 147 125kg 1730
35 Performance Guide 0 5 10 15 20 25 0 10 20 30 40 60 Air volume l/s Pressure Pa 30 35 40 50 70 2 1 Curve extraction performance Sound dB(A) SFP (W/l/s) Model setting Ref m 3 / hl/s Watts @ 3m @ 0Pa Lo-Carbon Silhouette 150B/T/HT Practical setting 1 200 55 6 35 0.11 Kitchen setting 2 234 65 9 43 0.14 Fixing hole diameter 152mmØ (when using wall mount kit)
dMEV, MEV and PIV system What are dMEV and MEV? The current building code approval document F gives examples of four main ventilation methods. System 3, continuous mechanical extraction and ventilation, can be achieved using a single centralized extraction device, such as Sentinel Multivent delivered from “wet” rooms (kitchen, bathroom, suite, and toilet) or by being dispersed in wet rooms. The fan runs continuously at a level close to silent, providing a simple and effective form of ventilation. Low-carbon response continuous operation, constant volume low-carbon response dMEV device has an innovative digital display. The unique display (patent pending) provides calibrated installation airflow and installation pressure, which means there is no need to use airflow measuring equipment to test the installation. Quiet operation and high-pressure development, Response is the best of its kind-this achievement was recognized when it won the Product of the Year award in the prestigious Housebuilder Awards in 2014.
Lo-Carbon Centra ® /SELV dMEV Unit 38-39 Lo-Carbon Response/SELV dMEV Unit 40-41 Lo-Carbon Multivent MEV Unit 42-43 Multivent MEV Unit 44-45 Lo-Carbon Sentinel ® Multivent/Plus MEV Unit 46- 49 Lo-Carbon Multivent MVDC-MS/MSH MEV device 50-51 Lo-Carbon PoziDry positive pressure device 52-53 Lo-Carbon PoziDry compact positive pressure device 54-55
38 Lo-Carbon Centra/SELV • Complies with building code approval documents F and L, system 3 continuous mechanical extraction • Approved in SAP PCDB-low SFP • Discreet and elegant shape • IPX4 rating-IPX7 rating (SELV) • dMEV pressure Testing device • 5-year motor warranty • Suitable for wall, ceiling, panel and window installations • SELV models are equipped with remote transformers and are suitable for “Zone 1″ What is distributed MEV (dMEV)? The building code approval document F gives examples of four main ventilation methods. System 3, continuous mechanical exhaust ventilation, can use a single centralized exhaust device (such as Sentinel Multivent pipe to “wet” room (kitchen, bathroom, suite and toilet) or scattered personal fans, such as Lo- “wet” room Carbon center. The fan runs continuously at a level close to silent, providing a simple and effective form of ventilation. SELV (Safety Extra Low Voltage) is designed to be used in areas where a fixed bathtub or shower fan can be installed in area 1. Entrance Protection (IP) to IPX7 Lo-Carbon Centra SELV can be safely installed in the spraying area. The independent transformer can be installed away from the spray area and the bathtub or shower. Lo-Carbon Centra complies with the building code approval document F for all The latest requirements for ventilation in housing systems, all models are provided with a 5-year motor warranty. Two trickle flow rates (6l/s or 9l/s) can be selected through a simple “jump” on the control panel. From simple live switching to integrated constant Humidifier, you can use different methods to operate the booster speed of 15 l/s. For more information, please refer to the individual models. The charming and discreet styling of the Vent-Axia Lo-Carbon Centra will complement the decoration of any new home, and almost Silent operation ensures optimal ventilation without intrusive noise. The specific fan power dMEV version identified in SAP PCDB. The specific fan power of Lo-Carbon Centra in through-wall kitchen applications is only 0.18 W/l /s. Model Lo-Carbon Centra dMEV automatically selects the speed during installation, suitable for bathrooms or kitchens. The integrated air pressure sensor checks the airflow during the first installation and also helps the fan to compensate for external wind pressure. Stock reference £Trade 441782 123.19 Lo-Carbon Centra T /SELV T (timer) is very suitable for bathroom and toilet applications. The device runs continuously for trickle setting, and can be enhanced by activating the switch real-time input of the timer (T model is fixed for 15 minutes, SELV model is adjustable for 5-30 minutes ). Model inventory reference £Trade T 442954 139.62 SELV T 443175 171.28 Lo-Carbon Centra TP/SELV TP (Timer/Drawstring) For bathroom/toilet applications, the continuous running TP model is enhanced by a drawstring that activates the timer (TP The model is fixed for 15 minutes, and the SELV model is adjustable for 5-30 minutes). Model stock Ref £Trade TP 44712​​7 156.68 SELV TP 44712​​8 187.67 Lo-Carbon Centra HT/SELV HT (humidifier/timer) Bathroom/toilet Application, the continuous running HT model automatically enhances the activation timer by the built-in humidistat or switched real-time input (HP model is fixed for 15 minutes, SELV model is adjustable for 5-30 minutes). Model stock Ref £Trade HT 442955 182.51 SELV HT 443176 214.44 WINNER 2011 Energy Efficiency Initiative Award Winner, our low-carbon continuous ventilation product series
39 Lo-Carbon Centra HTP/SELV HTP (Humidifier/Timer/Drawstring) For bathroom/toilet applications, the continuously running HTP model is automatically lifted by the built-in humidistat or drawstring that activates the timer (fixed on the HTP) 15 minutes) model, adjustable for 5-30 minutes on SELV model). Model stock Ref £Trade HTP 443045 182.51 SELV HTP 443177 214.44 Accessory model stock Ref £Trade 150mm Conversion kit 443334 28.65 Wall mount kit white 254102 21.55 Wall mount kit brown 254100 443178 Model 4 ABC 40mm 4 ABC 4 4 ABC 7 4 3 4 3 4 3 3 4 3 4 3 4 3 3 7 3 4 3 3 4 3 3 7 3 7 3 7 3 7 3 7 3 3 7 3 7 3 3 7 3 7 3 7 3 4 3 3 4 50mm model conversion kit Lo-Carbon Centra dMEV/All SELV 160 35 115 99 Lo-Carbon Centra T/TP/HT/HTP 160 35 80 99 Transformer 87 x 87 x 33mm (W x H x D) (only for SELV models) Performance guide Extraction performance (l/s ) Power consumption (Watts) Sound dB(A)@ 3m Trickle Trickle Trickle Trickle Trickle Trickle Model Low High Boost Low High Boost Low High Boost Lo-Carbon Centra dMEV/All SELV 6 9 15 1.4 1.6 2.4 10.8 15.5 25.2 Lo -Carbon Centra T /TP/HT/HTP 6 9 15 3.2 3.5 4.2 10.8 15.5 25.2 SAP PCDB performance (dMEV model) The system only installs rigid duct system unit configuration position fan speed setting flow rate (l/s) SFP (W/l) /s) indoor (Pipe type) kitchen height 13.2 0.32 indoor (pipe type) wet room 9 l/s 8.4 0.28 wall-through kitchen Hi gh 13.5 0.18 wall-through wet room 9 l/s 8.6 0.20 The system is only equipped with flexible or mixed duct system unit configuration Location fan speed setting flow rate (l/s) SFP (W/l/s) Indoor (duct) kitchen height 13.2 0.37 Indoor (ducted) wet room 9 l/s 8.6 0.31 Through-wall kitchen height 13.5 0.18 Through-wall wet room 9 l/s 8.6 0.20
40 Lo-Carbon Response/SELV • Approved in SAP PCDB • Constant volume • Display of air flow and system pressure (patent pending) • Live switch connection of external switch/sensor • 220-240V input • Daily recording function on Humidistat model • 6l/s or 8l/s trickle speed selection 13l/s boost speed • IPX4 grade-IPX7 grade (SELV) • Multi-directional grille • New comfort control option (patent pending) Low carbon response continuous operation, constant Capacity dMEV device with switching power supply (LS) and innovative digital display. Quiet operation and high-pressure development, the response is the best in its class. After Vent-Axia’s response fan introduced home ventilation compliance guidelines in Part F 2010, and required to test the installation airflow of the exhaust fan, Vent-Axia’s response fan provides the easiest installation. The unique display (patent pending) provides calibrated installation airflow and installation pressure, which means there is no need to use airflow measuring equipment to test the installation. Constant volume technology can automatically adjust the fan speed to ensure the required airflow. Lo-Carbon Response adopts a new type of silent high-pressure axial flow impeller, which can meet many domestic installation requirements without using traditional centrifugal fans. Axial, not centrifugal? Some centrifugal wind machines generate pressure, but the actual installed air flow may mean that the pressure is useless because the air flow is lower than required. Using the new high-pressure silent axial flow impeller, the fan can not only obtain excellent installation performance in pipeline operation, but also can be realized in the most energy-saving way. The response can provide excellent pressure while still maintaining energy efficiency and not wasting energy under high pressure with low air volume. This allows the fan to save up to 64% of the specific fan power (SFP) of SAP PCDB data for existing centrifugal alternatives. Configuration position spare centrifugal fan SFP Vent-Axia response SFP Indoor kitchen 0.38 0.17 Wet room 0.29 0.18 Wall kitchen 0.36 0.13 Wet room 0.28 0.15 0 20 40 0 ​​5 10 15 30 Flow/pressure 25 60 80 100 Pressure loss example (6m flexible pipe , 2x 90 elbow) unnecessary pressure that wastes energy Vent-Axia Lo-Carbon Response FanCompetitor Product 2 2 1 1 Airflow display side view Please believe that our Response is providing the correct performance. Innovative digital display shows the airflow of the installed product And system pressure. The comfort control option Lo-Carbon Response is designed to provide a more relaxing environment for homeowners, with a delayed start option. This new, patent-pending comfort control option can be selected during installation, allowing homeowners to enjoy a quiet and peaceful bathroom for up to 20 minutes before Boost is activated. In addition, if the light switch is turned on and off within 3 minutes, Boost will not be activated. If you turn on the bathroom lights at night, you will no longer disturb your family.
41 Model Lo-Carbon Response dMEV automatically selects the speed during installation. The integrated air pressure sensor checks the airflow when it is first installed and also helps the fan to compensate for external wind pressure. Stock reference £Trade 404535 136.94 Lo-Carbon Response/SELV TP (timer/pull cord) is suitable for kitchen, utility and bathroom/toilet applications. The continuously running TP model includes an adjustable overrun timer. This will adjust the time for the fan to continue boosting operation after the LS connection is disabled. This is also the running time of the drawstring. Model Stock Ref £Trade TP 404876 170.43 SELV TP 404878 200.84 Lo-Carbon Response/SELV HTP (humidifier/timer/rope) For kitchen, utility and bathroom/toilet applications, continuous operation HTP models include adjustable (40 %-90%) Environmental response humidistat. If the humidity rises above the point set during installation, the fan will increase the air extraction rate. Daily record for standard.Model stock reference £ Trade HTP 404877 196.26 SELV HTP 404879 228.19 Accessory Model Stock Reference £ Trade Barrier Package White 254102 21.55 Wall Kit Brown 254100 21.55 150mm Conversion Kit 408680 28.17 Ceiling Kit 40928 16.41 Window Accessories 407927 23.67 Decorative Frame 474041 11.00 Dimensions (mm) AB CØ D 90 45 99 190 BA CØ DD Performance Guide 0 20 10 30 40 50 0 5 10 15 20 25 30 Pressure P a Volume flow l/s 13l/s Constant volume can provide maximum pressure air flow 6l/ s Constant volume 8l/s Constant volume 1 2 3 4 1 2 3 4 Extraction performance l/s (m 3 /h)-FID Watts dB(A) @ 3m Model Trickle Low Trickle High Boost Trickle Low Trickle High Boost Trickle Low Trickle High Boost Lo-Carbon Response 6 (21) 8 (29) 13 (43) 1.0 1.2 1.7 12 17 32.5 SAP PCDB Performance Unit Configuration Location SFP (W/l/s) In room (rigid duct) Kitchen 0.17 In room (rigid Pipe) Wet room 0.18 In the room (flexible pipe) Kitchen 0.17 In the room (flexible pipe) Wet room 0.16 Wall-through kitchen en 0.13 Wall-through wet room 0.15
42 Lo-Carbon Multivent continuous mechanical extraction ventilation series is designed for simultaneous ventilation of different areas of the home or as a multi-point extraction system for a wide range of commercial applications. In the home, the system is usually located in the attic or fume hood, with ducts leading to bathrooms, utility rooms and toilets to remove air pollutants such as water vapor and odors. Lo-Carbon Multivent is ideal for a range of commercial applications, such as toilets, fitting rooms and kiosks. These devices can be installed at any angle, and provide condensate drains where the ambient air humidity is high. The Lo-Carbon Multivent H version includes a built-in humidity sensor that can switch between two of the three speeds. The wireless controller can be used with Lo-Carbon Multivent H and has three speed options to provide full control of the system. Low-carbon MVDC Lo-Carbon MVDC Multivent uses the latest DC technology to minimize operating costs. DC efficiency means less wear on the motor, which guarantees a longer service life. Extend the motor warranty period to 5 years. Model CAS Model Stock Ref £Trade MVDC 181520 298.22 MVDCH 183020 323.07 Accessories Acoustic Lining Kit CAS Used to reduce noise in sensitive devices Stock Ref £Trade 438195 20.06 Multivent Wireless Controller CAS (only for MVDCRef.26Trade 323.05 Automobile 323.07 Automobile) Stock • Reduce your carbon footprint. • EC low energy consumption motors. • Equipped with four sockets with a diameter of 100 or 125 mm for quick connection to pipes. • Wall, ceiling and attic installations are available. • Quiet operation and suitable for continuous operation. Extract from each room, depending on the residence• Wireless controller is available
43 Dimensions (mm) Weight: 5.50kg AJIECB Ø125 HDF ​​G Diameter of reducing parts: 100/125mm ABCDEFGHIJ 340 72.5 25 15 360 214 310 249 150 85 Technical performance curve low/high SEC high/high mLU3 ME (inc. LDC) Current Power Current Power Current Power Model Amps Watts Amps Watts Amps Watts SEC Class MVDC 0.1 9 0.23 20 0.39 44 EB MVDCH 0.1 9 0.23 20 0.39 44 DB Sound Level Sound dB(A) @ Per 3m FID Casing duct inlet duct inlet model Speed ​​m 3 /h (l/s) Breakout 100mmØ 125mmØ MVDC Low 232 (64) 33.3 36.5 36.5 Medium 365 (100) 33.7 47.9 47 High 434 (1876) 434 (1826) 435VDC Low 125H 5H 435 33.3 36.3 36.5 Medium 365 ( 100) 33.7 47.9 47 High 434 (120) 38.8 51.7 51.5
44 Multivent • Equipped with four sockets with a diameter of 100 or 125 mm for quick connection to pipes • Wall, ceiling and attic installation methods can be selected • Quiet operation, suitable for continuous operation • Can be extracted from multiple rooms, depending on the residence • Provide wireless controller Multivent continuous mechanical exhaust ventilation range designed for simultaneous ventilation of different areas in the home or as a multi-point exhaust system for a wide range of commercial applications. In the home, the system is usually located in the attic or fume hood, with ducts leading to bathrooms, utility rooms and toilets to remove air pollutants such as water vapor and odors. Multivent is ideal for a range of commercial applications, such as toilets, fitting rooms and kiosks. These devices can be installed at any angle, and provide condensate drains where the ambient air humidity is high. The Multivent H version includes a built-in humidity sensor that can switch between two of the three speeds. The wireless controller can be used with Multivent H and has three speed options to provide full control of the system. Model CAS Model Stock Ref £Trade MV250 181510 250.95 MV250H 183010 287.26 Accessories Soundproof Lining Kit CAS Used to reduce noise in sensitive devices Stock Ref £Trade 438195 20.06 Multivent Wireless Controller CAS (only for MV25010 287.26 and 183010 287.26 Refrade 183010 287.26)
45 Dimensions (mm) Weight: 5.50kg AJIECB Ø125 HDF ​​G Diameter of reducing parts: 100/125mm ABCDEFGHIJ 340 72.5 25 15 360 214 310 249 150 85 Technical performance curve/low VO high mh medium and low mME 3 ME (inc. LDC) Current Power Current Power Current Power Model Amps Watts Amps Watts Amps Watts SEC class MV250 0.2 25 0.30 54 0.34 81 EC MV250H 0.2 25 0.30 54 0.34 81 EC sound level @ F sound level 3 dBm(F) m 3 /h (l/s ) Casing tap pipe inlet 100mmØ Pipe inlet 125mmØ MV 250 Low 161 (45) 22.4 27.9 27.8 Medium 305 (85) 31.0 42.9 43.2 High 443 (450) 480 4H 443 (450) 4H 480 4H 22.4 27.9 27.6 Medium 344 (95 ) 31.0 42.9 43.2 High 443 (123) 35.4 48.6 48.0
46 Lo-Carbon Sentinel Multivent/Plus • Reduce carbon footprint • Recognized in SAP PCDB • Specific fan power 0.16 W/l/s (K+1) • Suitable for external sensors and controllers • Wireless control options • Compliant with building standards Regulations ADF and ADL • Manufactured in the UK, using the recyclable material Sentinel Multivent continuous mechanical extraction and ventilation, MEV is designed for simultaneous ventilation of different areas of the home or as a multi-point extraction system for a wide range of commercial applications. These devices can be installed at any angle. Set up a condensate drain pipe in a place with high ambient air humidity. To support Sentinel Multivent, Vent-Axia provides: • Practical advice on product selection and installation • Solutions guide to meet regulatory requirements • Project management and on-site delivery • After-sales support and maintenance information Sentinel Multivent aims to increase efficiency to satisfy developers and installations The strict requirements of personnel and users provide advanced control options and easier installation and commissioning. • Demand control-to achieve precise ventilation rate, set in 1% increments according to the size of the property • Integrated LCD display allows installers to select the appropriate low, normal and acceleration speeds to meet demand • Manual and automatic control options • Integrated adjustable Overspeed timer and timer delay • Plug-and-play automatic sensor detection • Switch real-time and SELV connection • Drying settings – set options during installation, Sentinel Multivent will run on pressurization for 1 week to help remove moisture • Optional wireless control – up to 4 Controller on any system • Energy-saving EC/DC motor-1/3 less heat loss than traditional AC motors • Low specific fan power (SFP) makes it one of the most efficient products on the market. Legislation • Complies with building regulations Approval Document F (System 3) • Be recognized in the SAP PCDB until the kitchen + 6 wet rooms • Achieve the goal of reducing carbon footprint • Any demand control MEV system minimum SFP number The need for bette r Healthy removal of moisture, carbon dioxide and Pollutants such as external smog are important factors to maintain indoor air quality and help create a healthier living environment. • The integrated humidity sensor (Sentinel Multivent H) increases the fan speed based on the relative humidity level, saving energy and reducing noise. The sensor will respond to small but rapid increases in humidity even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even in the smallest wet room. • The night-time relative humidity increment retreat function can suppress false trips due to the gradual increase in humidity as the temperature drops. • Acoustic lining-low noise level of only 18.1 dB( A) @ 3m SAP PCDB In order to make the right choice, developers and contractors should refer to the building codes ADL1a, SAP 2012 and SAP PCDB. SAP PCDB was launched in June 2006 to reward innovative ventilation manufacturers by testing and listing energy-saving products that help developers reach target emission rates (TER). SAP is the basic method behind the Energy Performance Certificate and is used to demonstrate compliance with residential building regulations-Approval Document L (England and Wales), Section 6 (Scotland) and Approval Document F (Northern Ireland). SAP PCDB specifically deals with whole-house ventilation systems and lists many Vent-Axia mechanical ventilation solutions that provide improved SAP ratings that are higher than the default values ​​for these product types.
47 SEC level model SEC level Sentinel Multivent/Plus C SAP PCDB test results (Sentinel Multivent) Exhaust terminal fan speed total configuration setting flow SFP (W/l/s) K+1 32% 21 0.16 K+2 39% 29 0.16 K+3 49% 37 0.17 K+4 59% 45 0.21 K+5 68% 53 0.24 K+6 77% 61 0.29 SAP PCDB test result (Sentinel Multivent Plus) exhaust terminal fan speed total configuration setting flow SFP (W/ l/s) K+1 20% 21 0.25 K+2 25% 29 0.22 K+3 30% 37 0.22 K+4 34% 45 0.22 K+5 40% 53 0.25 K+6 45% 61 0.27 Assist developers in contracting Vent-Axia can provide detailed program design, installation guidance and training. Your carbon footprint Carbon footprint is a measure of the amount of carbon dioxide (CO 2) emitted from burning fossil fuels. From the perspective of residential and commercial buildings, it is the amount of carbon produced when you consume one kilowatt of electricity. Reducing the carbon footprint of buildings will ultimately reduce electricity bills and save money for every household or business. It will also help achieve the UK’s emissions reduction goals and allow you to help protect the environment. Model stock reference £ Trade Sentinel Multivent 437601 447.96 Sentinel Multivent H 445655 480.23 Sentinel Multivent plus 407001 515.60 Sentinel Multivent plus H 407849 544.24 Dimensions (mm) AJIECB Ø 125 HDF ​​G reduction piece diameter: 100/125 mm ABCDEFGHIJ 340 72.5 25 15 360 214 310 260 150 85
48 Performance Guide 0 100 200 300 400 500 600 700 0 20 40 50 0 200 250 300 100 150 350 400 450 500 550 600 650 1 s 0 1 0 s 0 1 0 s 0 650 1 s 0 1 0 s 0 1 0 s 0 1 0 s 0 Multivent Sentinel Multivent Plus 1 2 Stock Ref Model Curve Ref Inlet Duct dB(A) FID l/s Power Watts SEC Class (inc. LDC) SEC Class 437601/445655 Multivent 1 (max) 38 121 45 EC 407001 / 407299 (max)-165 83 EC Sound Data (Sentinel Multivent) Induced sound power level dB dB(A) Speed ​​63 125 250 500 1K 2K 4K 8K @ 3m 10% Breakout 43.6 37 36.9 30.6 26.2 .36139 8 .8 3 3 3 3 8 24.6 21.8 30.3 22. 17.8 28% 44 Breakout 44.4 43.3 31.1 39 26.1 24.3 30.1 22 42.2 Extract 40.1 42.2 40.5 23.3 32 23.4 30.5 22 46% 45 Breakout 42.8 46.7 44.1 38.8 35.6 26.7 30.6 25.8 40.8 Extract 42.5 46.4 44.4 31.1 41 25.3 30.3 26 82% Breakthrough 46.3 48.3 50 52.1 48.4 47.7 37.8 32.4 33.7 Extract 46.7 49.6 48.9 54.3 51.8 42.7 38.1 34.2 Hz 36.1 dB Multi-channel data, multi-channel sonic data, multi-channel sonic data SPL speed% test mode 63 125 250 500 per thousand 2K 4K 8K decibels (A) at 3 meters 20 entrance 45.0 46.0 43.9 34.1 27.4 22.8 23.1 29.7 20.5 exit 45.0 40.9 45.2 39.5 33.0 26.7 23.0 29.1 29.5 Breakout 43.9 37.4 36.5 35.5 26.7 22.6 23.7 30.2 19.0 40 entrance 48.6 48.7 54.4 52.3 55.4 47.5 38.0 33.1 37.0 exit 49.1 54.6 54.4 55.0 55.7 51.7 39.7 39.5 42.9 breakout 45.2 44.2 47.5 46.1 40.0 34.0 26.3 30.3 26.8 60 entrance 48.6 48.7 54.4 52.3 55.4 47.5 38.0 33.1 37.0 exit 57.1 55.9 65.2 63.3 64.8 64.5 53.7 55.5 52.2 Breakout 49.0 49.7 58.0 53.7 48.4 46.4 36.4 33.3 34.9 80 Entry 56.3 56.6 60.4 59.0 61.4 56.0 46.6 43.5 43.5 Exit 62.3 60.8 70.9 69.3 69.5 70.3 61.9 62.8 57.9 Breakout 53.1 53.7 61.8 61.4 53.4 54.5 44.9 41.9 41.3 100 Entry 54.1 55.5 59.4 61.8 62.7 58.9 49.7 45.8 45.3 Export 63.1 61.8 67.8 72.7 70.5 71.5 62.9 64.4 59.0 Breakthrough 56.5 54.3 60.8 65.6 4.6426 54.3465
49 All-in-one humidistat • Simple plug-and-play installation • No additional controllers or sensors required • Respond to any rapid increase in relative humidity or humidity rises above an adjustable threshold • Future-proof-can be installed Post-installation • Self-programming inventory reference £Trade 437598 45.55 Environmental response humidity sensor • Cord cover and indicator light • Changeover relay switch • Operating range: 30%-90% RH • Ambient operating temperature. 5°C to 40°C • 220-240V AC • Single box Stock Ref £Trade 563550 200.83 Visonex PIR sensor suitable for surface mounting • Suitable for any UK single box • Adjustable timer timeout (5-25 Minutes) • Range detection distance up to 10 meters • Design meets IP43 • Ambient operating temperature. Range 0°C to 50°C Stock reference £Trade 459623 115.70 Wireless transmitter controller receiver kit • Manual boost • Adjustable overrun timer • Easy wireless installation • Reduce installation time • Future-proof-add more controls at any time Monitor inventory reference £Trade 439352 91.11 Ecotronic humidity sensor • Adjustable set point • Maximum switching load 1 ampere inductance • Pull cord coverage indicator • Ambient operating temperature. 0°C to 40°C • Power supply voltage 220-240V Stock Ref £Trade 563532 111.57 CO 2 + temperature room sensor IND • 240V DC • 0-2000ppm CO 2 working range • 0-50°C working range • automatic calibration NDIR CO 2 Absorption sensor • High-precision thin-film platinum temperature sensor stock Ref £Trade 433257 577.47 Wireless transmitter controller CAS • Additional controller for 439352 • Up to 4 controllers per system • Can be connected to other accessories (such as Humidistat) wireless Send enhanced signal Stock Ref £Trade 437827 53.16 Air quality sensor GEN • Ambient operating temperature. 0°C to 50°C • DEMKO approved • Surface mount • 1-25 minutes O/R timer • Power supply voltage 220-240V Stock Ref £Trade 563506 223.74 Ventwise CAS • When the supply pipe to the shower or bathtub is added • When the electric stove is turned on Auto-enhanced fan • Can be used in conjunction with manual override input • Adjustable overrun timer • Two sensor options available Stock reference £Trade 435960 391.10 Controllers and sensors Sentinel Multivent can be used with a variety of Vent-Axia controllers and sensors. From the integrated humidistat to the wireless controller, to the wired remote sensor.
50 With increasing concerns about accurate ventilation of properties, the low-carbon Multivent MVDC series provides a “close control” option for residential and commercial areas. Using a DC motor, the multi-speed Lo-Carbon Multivent is one of the most efficient central extraction devices. These devices have two fully variable trickle and boost speeds, as well as switched real-time (LS) activation for boost speed. Using a second live switching connection provides an additional third speed (purge). The standard sound-absorbing lining ensures that noise is minimized. The speed selector controlled by the potentiometer can accurately set the airflow to ensure the correct ventilation rate. This feature can also reduce noise and energy consumption. Model CAS Stock Ref £Trade MVDC-MS 437634 356.69 MVDC-MSH 443298 385.33 SAP PCDB test results total exhaust terminal configuration flow SFP (W/l/s) K + 1 21 0.16 K + 2 29 0.15 K +0 3 + 4 45 0.20 K + 5 53 0.24 K + 6 61 0.28 Lo-Carbon Multivent MVDC-MS/MSH • Best-in-class specific fan power • Reduce your carbon footprint • Recognized in SAP PCDB • Equipped with four diameters of 125 or The 100 mm socket allows quick connection to the pipeline • Compliant with architectural ADF (System 3) • Wall, ceiling and attic installations can be selected • Improved controllability • Switchable Live Boost connection • Fully variable normal and boost speeds • Ultra quiet -Acoustic lining to reduce noise level • Integrated humidistat (H version)
51 Dimensions (mm) Weight: 5.50kg AJIECB Ø125 HDF ​​G Diameter of reducing parts: 100/125mm ABCDEFGHIJ 340 72.5 25 15 360 214 310 249 150 85 Performance guide MVDC integrated humidity device to improve performance when humidity 70%. 0 50 100 150 200 250 300 350 400 450 0 20 40 50 0 200 200 250 300 100 150 350 400 450 60 80 1010 1 0 s Maximum speed 1 Minimum speed / 10 10 seconds Maximum speed 3 Pa Fully adjustable 2 2 Minimum maximum Model casing breaks dB(A) @ 3m inlet pipe dB(A) FID l/s power watts casing breaks dB(A) @ 3m inlet pipe dB(A) FID l/s power watt SEC class SEC class (including LDC ) MVDC-MS 19 18 43 6 37 38 121 45 EB MCDC-MSH 19 18 43 6 37 38 121 45 EB